Typ C40 / 110T.B. 10/2003EnglishENMANUALABSORPTION REFRIGERATORfor RECREATIONAL VEHICLESRM 6290 LD(H)RM 6291 LD(H)RM 6400 LD(H)RM 6401 LD(H)OPERATING
10Winter operation1. Check that the ventilation grills and the extractor have not been blocked by snow, leaves or similar.Interior light (when fitted)
11Changing the decor panelPositioning the storage rackTo fit the storage rack, the reverse order applies.5.105.11Dismantling:1. Loosen the front and b
12TroubleshootingMaintenance EN 1949 stipulates that the appliance´s gas equipment and its associated fume system must be inspected after installati
13Environmental hintsRefrigerators manufactured by Dometic GmbH are CFC-free.Ammonia (a natural compound of hydrogen and nitrogen) is used in the cool
14Declaration 5.18
15INSTALLATION GUIDEOn installation of the appliance, the technical and administrative regulations of the country in which the vehicle will first be u
16Draught-free installationThe refrigerator must be sealed in accordance with EN 1949.Illustrated below are two typical approved methods of sealing.Pr
17If even with draught-free installation a fume chimney is desirable, you must incorporte the L100 ventilation and extraction system into the upper ai
18Installing the ventilation system6.43. Insert the ventilation grilles.6. Insert winter cover2. Insert the frame ...4. Lock the ventilation grilles.
19Installation recessThe refrigerator must be installed draught-free in a recess.The measurements of the recess are given in the table below.Step (A)
2These operating instructions should be kept in a safe place.If this device is passed on, please include these operating instructions with it.© Dometi
20Fume extractionFume extraction must be arranged in such a way as to provide complete extraction of all products of combustion to an area outside the
21Separate fume extraction1. Cut an 80mm x 40mm rectangle in the outerwall of the caravan. The position of the cut must be appropriate to the particul
22The gas connection to the appliance is effected by means of a suitable coupling tube fitting L8, DIN 2353-ST, complying with EN 1949. (e.g. Ermet
23Electrical installationElectrical installation may only be carried out by qualified personnel.The connection cables must be laid in such a way that
24Wiring diagrams1. Wiring diagram with manual ignition and no interior light.2. Wiring diagram with manual ignition and interior lightbattery connect
253. Wiring diagram with automatic ignition and no interior light4. Wiring diagram with automatic ignition and interior lightspark pluglight DC --reed
Dometic GmbHIn der Steinwiese 16D-57074 Siegenwww.dometic.de/caravanwww.dometic.com
31.0 INTRODUCTION 42.0 FOR YOUR SAFETY 42.1 Warning and safety notices 42.2 Coolant 4 3.0 WARRANTY AND CUSTOMER 5SERVICE3.1 Damage in transit 54.0 DE
4INTRODUCTIONYou have made an excellent choice in selecting the Dometic Absorption Refrigerator. We are sure that you will be fully satisfied with you
5WARRANTY AND CUSTOMER SERVICEWarranty arrangements are in accordance with EC Directive 44/1999/CE and the normal conditions applicable for the countr
6Using the refrigerator The refrigerator is silent in operation. When the appliance is first put into operation, there may be a mild odour which wil
7Electrical operation1. 12V DCThe refrigerator should only be used while the motor is running.1. Set energy selector switch (A) to.The refrigerator op
85. Keep rotary switch (B) depressed for another 10-15 seconds, then release.6. Check the inspection glass to see whether a flame is burning.7. Repeat
9DefrostingAs time goes by, frost builds up on the fins.When the layer of frost is about 3mm thick, the refrigerator should be defrosted.1. Switch off
Comments to this Manuals