Electrical Connection
The oven is designed to be connected
to 230-240V~(50Hz) electricity supply.
The oven has an easily accessible termi-
nal block which is marked as
follows:
This oven must be earthed!
The cable used to connect the oven to
the electrical supply must
comply to the specifications given be-
low.
For UK use only
It is necessary that you install a double
pole switch between the oven and the
electricity supply (mains), with a mini-
mum gap of 3mm
between the switch contacts and of a
type suitable for the required load in
compliance with the current regulations.
The switch must not break the yellow
and green earth cable at any point.
Important
After installation and connecting, the ca-
ble must be placed so that it cannot at
any point reach a temperature of more
than 50°C above the ambient tempera-
ture.
Before the oven is connected, check
that the main fuse and the domestic in-
stallation can support the load; and that
the power supply is properly earthed.
The manufacturer declines any re-
sponsibility should these safety
measures not be carried out.
Letter L - Live terminal
Letter N - Neutral terminal
E - Earth terminal
Connec-
tion
via
Min.
size
Cable/
flex
Cable/
flex
type
Fuse
Cooker
Control
Circuit
2,5 mm
2
PVC/PVC
twin and
earth
min:
15A
max:
20A