Installation
Setting the Temperature Controls
Cool Down Period
Forsafe food storage, allow four (4) hours for freezerto cool down completely. The freezerwill run continuously for
the first several hours.
Electronic Temperature Control
The electronic temperature control is located on the freezer door. Temperature is factory preset to provide
satisfactory food storage temperatures. Refer to the SETTING FREEZER CONTROL Quick Reference
Guide below for more details.
SETTING FREEZER CONTROL
Press to start or
canceI the fast --
freeze feature.
Press to
decrease the
temperature
setting
Press and Turns the Press to
hold for 3 temperature mute
seconds to display ON or audible
toggle F or C OFF. alarms.
in the display. _/
f
Press to turn the
sounds ON or OFF.
When the LED is ON,
the sounds are muted.
m door aja_ u tern[ B po_,_ie_fsl
-f t
indicates the
Indicates the temperature was Indicates the
door has been above +23°F (-9°C) power was
open 5 minutes for at least one interrupted.
or more. hour.
Press and hold
for 3 seconds to
start or cancel
control lock.
Press to
increase the
temperature
setting
ALARM FUNCTION TABLE
"HI"
Alternating "El"
and temperature
Alternating "CE"
and temperature
Alternating "E2"
and temperature
Actual
Temperature
4
6
5
"HI Temp" LED ON and
mute sounds LED flashes
mute sounds LED flashes; 1
second set temperature, 1
second "El"
mute sounds LED flashes; 1
second set temperature, 1
second "CE"
mute sounds LED flashes; 1
second set temperature, 1
second "E2"
power fail LED on and mute
sounds LED flashes
Freezer temperature
over the safe limit
Fail Safe Mode
Communication Error
Stuck Key Error
Cabinet greater than 10
degrees over the SET
TEMP. at power up.
Door open for more than
5 minutes
Press the mute sounds key
the audible alarm
Checl< thermistor status
Press the mute sounds key
to stop the audible alarm
Check connection between
UI and ECU. Press the mute
sounds key to stop the
audible alarm
Check membrane keys.
Press the mute sounds key
to stop the audible alarm
Press the mute sounds key
to stop the audible alarm
Set Temperature door ajar LED on and mute Press the mute sounds key
sounds LED flashes to stop the audible alarm