Problem Possible cause Remedy
The appliance does
not heat up.
The clock is not set. Set the clock.
The appliance does
not heat up.
The necessary settings are
not set.
Check the settings.
The appliance does
not heat up.
The Child Lock is activated. Refer to "Activating and de-
activating the Child Lock
function".
The appliance does
not heat up.
The door is not closed cor-
rectly.
Fully close the door.
The appliance does
not heat up.
The fuse is released. Make sure that the fuse is
the cause of the malfunc-
tion. If the fuse releases
again and again, contact a
qualified electrician.
The lamp does not
operate.
The lamp is defective. Replace the lamp.
If you cannot find a solution to the prob-
lem yourself, contact your dealer or the
service centre.
The necessary data for the service centre
is on the rating plate. The rating plate is
on the front frame of the appliance cavity.
We recommend that you write the data here:
Model (MOD.) .........................................
Product number (PNC) .........................................
Serial number (S.N.) .........................................
14. INSTALLATION
WARNING!
Refer to the Safety chapters.
The built-in unit must meet the
stability requirements of DIN
68930.
The oven is designed to be connected to
230 - 240V ~ (50Hz) electricity supply.
The oven has an easily accessible termi-
nal block which is marked as follows:
Letter L - Live terminal
Letter N - Neutral terminal
- Earth terminal
CAUTION!
This oven must be earthed!
The cable used to connect the oven to
the electrical supply must comply to the
specifications given below.
For UK use only
Connection via Min. size Cable/
flex
Cable/flex type Fuse
Cooker Control
Circuit
2,5 mm² PVC / PVC twin
and earth
min: 15 A
max: 20 A
It is necessary that you install a double
pole switch between the oven and the
electricity supply (mains), with a minimum
gap of 3 mm between the switch contacts
and of a type suitable for the required
load in compliance with the current regu-
lations.