Electrolux 75100 GA User Manual Page 22

  • Download
  • Add to my manuals
  • Print
  • Page
    / 28
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 21
What to do if ...
22
Symptoms Possible Cause Remedy
The freezer temperature is
not sufficient, red light
illuminates, temperature
alarm signal sounds.
Temperature is not proper-
ly adjusted.
A large quantity of warm
food placed in the appli-
ance within the last 24
hours.
Please look in the “Initial
Start Up” section.
Press the FROSTMATIC
button.
Do not leave the door
open any longer than nec-
essary. Press the fast freeze
switch.
Door was open for an
extended period.
The appliance is near a
heat source.
Please look in the
“Installation Location” sec-
tion.
Heavy build up of frost,
possibly also on the door
seal.
Door seal is not air tight
(possibly after reversing
the door).
Carefully warm the leaking
sections of the door seal
with a hair dryer (on a
cool setting). At the same
time shape the warmed
door seal by hand such
that it sits correctly.
Unusual noises.
Appliance is not level.
The appliance is touching
the wall or other objects.
Readjust the feet.
Move the appliance slight-
ly.
The compressor does not
start immediately after
changing the temperature
setting.
This is normal, no error has
occurred.
The compressor starts after
a period of time.
Important: regularly check on the red temperature pilot light and tem-
perature display to establish that the storage temperature is being
maintained.
Page view 21
1 2 ... 17 18 19 20 21 22 23 24 25 26 27 28

Comments to this Manuals

No comments