SERVICE MANUAL DRYERS © ELECTROLUX ZANUSSI S.p.A. Spares Operations Italy Corso Lino Zanussi, 30 Publication No. I - 330
SOI/ADL 9/57 599 38 46-21 4.5 Humidity level (on some models) By pushing this button it is possible to select one of the three different final dry
SOI/ADL 10/57 599 38 46-21 4.8 No buzzer button Option to be selected when the dryer is in selection mode (set-up). Press this button to exclud
SOI/ADL 11/57 599 38 46-21 4.9 Delayed start button Pressing this button it is possible to select, during the programme selection phase,
SOI/ADL 12/57 599 38 46-21 4.11 Adjusting the level of conductivity (on some models) The conductivity of the water used to wash the fabrics varies
SOI/ADL 13/57 599 38 46-21 Display Conductivity Approximate value (μS/cm) Low < 300 Medium 300 - 600 High > 600 Normally, the ap
SOI/ADL 14/57 599 38 46-21 5 Description of operation of the appliance When the selector is turned from OFF position to a drying programme, the i
SOI/ADL 15/57 599 38 46-21 5.3 Operation in DELAYED START mode After selecting a drying cycle, press this button to enter the delayed start option
SOI/ADL 16/57 599 38 46-21 6 STRUCTURAL AND FUNCTIONAL CHARACTERISTICS 6.1 Drying circuit Version with canister in upper section Version with cani
SOI/ADL 17/57 599 38 46-21 6.2 Structural characteristics Version with canister in upper section Version with canister in lower section 1 – Wor
SOI/ADL 18/57 599 38 46-21 6.3 Drum 1 – Front flange 2 – Drum housing 3 – Rear flange 4 – Drum lifters 5 - Plastic band The drum consists
SOI/ADL 1/57 599 38 46-21
SOI/ADL 19/57 599 38 46-21 6.5 Hydraulic circuit (versions with canister in upper section) 1 – Pump immersed in the sump 2 – Water fill hose t
SOI/ADL 20/57 599 38 46-21 7 ELECTRICAL COMPONENTS 7.1 EDR2000 Electronic control The electronic control consists of a main electronic board fitted
SOI/ADL 21/57 599 38 46-21 7.1.2 General structure of board memory The system features an EEPROM, positioned externally to the microprocessor, whic
SOI/ADL 22/57 599 38 46-21 7.2 Conductimetric sensor The conductimetric sensor consists of an electronic circuit (positioned inside the power board
SOI/ADL 23/57 599 38 46-21 7.4 Heater unit 1 – Filament heating element 2 - Ceramic supports 3 - Sheet metal casing 4 - TH1 Safety therm
SOI/ADL 24/57 599 38 46-21 7.6 Motor 1 – Fan (inclined blades for cold air circulation) 2 – Belt tensioner 3 – Motor 4 – Fan (straight blades
SOI/ADL 25/57 599 38 46-21 7.8 Door interlock The door interlock is an electromechanical device which powers the electrical loads only when the d
SOI/ADL 26/57 599 38 46-21 8 ELECTRICAL CIRCUIT
SOI/ADL 27/57 599 38 46-21 9 DIAGNOSTICS SYSTEM In diagnostics mode, it is possible to check the operation of the appliance and to read the alarm c
SOI/ADL 28/57 599 38 46-21 IMPORTANT! ¾ The alarms remain active during component diagnostics testing. If an alarm should be displayed, turn th
SOI/ADL 2/57 599 38 46-21 INDICE 1 Purpose of this Manual...
SOI/ADL 29/57 599 38 46-21 9.3 Selector positions for diagnostics on appliances with styling TC2 – TC3 – TC4 WARNING When the various funct
SOI/ADL 30/57 599 38 46-21 8 ¾ Conductimetric sensor. This check has a duration of 4 sec. The phase/warning LEDs flash during this period. If
SOI/ADL 31/57 599 38 46-21 9.4 Selector positions for diagnostics on appliances with styling TC6 Selector position Components activated Operatin
SOI/ADL 32/57 599 38 46-21 10 ALARMS 10.1 Displaying the alarms to the user Operation of the alarms is configurable according to the model. Some o
SOI/ADL 33/57 599 38 46-21 10.3 Cancelling the last alarm memorized It is good practise to cancel the alarm code from memory: • After reading the
SOI/ADL 34/57 599 38 46-21 10.5 Table of alarms Alarm Description Possible fault Action/machine status Reset command E00 No alarm. --- --- -
SOI/ADL 35/57 599 38 46-21 E61 Insufficient heating (maximum time exceeded). Heater unit faulty; Wiring faulty; NTC sensor incorrectly calibrated/o
SOI/ADL 36/57 599 38 46-21 EB1 Power frequency to appliance out of limits. Problems with the power supply (incorrect/interference). Electronic boar
SOI/ADL 37/57 599 38 46-21 11 NO ACCESS TO DIAGNOSTICS PROGRAMME 11.1 No LEDs on the display board light YES NO YES NO YES NO NO NO SI NO SI YES
SOI/ADL 38/57 599 38 46-21 11.2 Some of the LEDs on the display board light NO SI NO Repair the mechanical problems (control panel, pushbutton
SOI/ADL 3/57 599 38 46-21 11.2 Some of the LEDs on the display board light...
SOI/ADL 39/57 599 38 46-21 12 ACCESSIBILITY TO COMPONENTS If an electric screwdriver is used, ensure that the screws are not tightened excessively!
SOI/ADL 40/57 599 38 46-21 12.2 Work top The following components can be accessed from the work top: - Front brush - Control panel - Control p
SOI/ADL 41/57 599 38 46-21 12.2.3 Control panel support and Control panel • Remove the canister and unscrew the screw which fixes the water fill
SOI/ADL 42/57 599 38 46-21 12.2.4 Main electronic board To remove the main electronic board: • Remove screw A which secures the selector protecti
SOI/ADL 43/57 599 38 46-21 12.3 Removal of both cover and rear panel gives access to: 12.3.1 Heater unit • Unscrew the screws (1) which secure t
SOI/ADL 44/57 599 38 46-21 12.3.2 Removal of the left-hand side panel gives access to: - The floating microswitch - The float - The pump - The
SOI/ADL 45/57 599 38 46-21 12.3.4 Float The float is located inside the sump. To remove the float, turn it 90° clockwise as shown in the figure
SOI/ADL 46/57 599 38 46-21 12.3.6 Door interlock Remove the two screws which secure the interlock to the front panel and remove the interlock.
SOI/ADL 47/57 599 38 46-21 12.4 Removal of the right-hand side panel gives access to: - The motor capacitor - The starting capacitor - The hot
SOI/ADL 48/57 599 38 46-21 12.4.2 NTC Sensor Remove the sensor from the seal Detach the connector 12.4.3 Rear air duct cover (hot air
SOI/ADL 4/57 599 38 46-21 1 Purpose of this Manual The purpose of this Service Manual is to provide service engineers who already have the basic
SOI/ADL 49/57 599 38 46-21 12.4.5 Drum rotation motor After removing the covers from the two ducts, it is possible to access the drum rota
SOI/ADL 50/57 599 38 46-21 12.5 Removal of the front panel gives access to: - The capacitor (heat exchanger) - The flap door - The plinth - Th
SOI/ADL 51/57 599 38 46-21 12.5.3 Plinth • To remove the plinth: remove the screw which secures it to the front panel, move it towards the centr
SOI/ADL 52/57 599 38 46-21 12.6 Removal of the rear panel gives access to: - The rear brush - The drive belt - The drum - The duct - The duct
SOI/ADL 53/57 599 38 46-21 12.6.5 Duct • Remove the work top. • Remove the rear panel. • Remove the drum. • Unscrew the screws which secure it
SOI/ADL 54/57 599 38 46-21 13 REVERSIBILITY OF THE DOOR Proceed as follows: 1. Remove the screws which secure the hinges to the cabinet (fig.A.1)
SOI/ADL 55/57 599 38 46-21 18. Remove the hinges by removing the hinge screws (fig.F-6). 19. Remove the hinge hole masking caps (fig.F-7). 20.
SOI/ADL 56/57 599 38 46-21 14 FINAL TESTING OF DOOR CLOSURE In order to check that the door closes correctly (i.e. in compliance with safety standa
SOI/ADL 5/57 599 38 46-21 3 GENERAL CHARACTERISTICS 3.1 Technical data Dimensions of appliance Height: Width: Depth: 85 cm 60 cm 58 cm Power s
SOI/ADL 6/57 599 38 46-21 4 CONTROL PANEL 4.1 Stylings With LCD TC2 TC3 With LED TC4 TC6 4.2 Programme selector The 15-position pr
SOI/ADL 7/57 599 38 46-21 4.3 Buttons 4.3.1 Buttons on stylings with and without LCD TC2 TC3 TC4 TC6 1. Configurable button 2. C
SOI/ADL 8/57 599 38 46-21 4.4 Symbols on stylings with LCD The various icons and writings represented on the LCD display are displayed depending
Comments to this Manuals