Electrolux EI15IM55GS User Manual Page 2

  • Download
  • Add to my manuals
  • Print
  • Page
    / 2
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 1
Under-Counter Ice Maker
EI15IM55G S
High standards of quality at Electrolux Home Products, Inc. mean
we are constantly working to improve our products. We reserve the right
to change specifications or discontinue models without notice.
Electrolux Major Appliances, N.A.
USA
10200 David Taylor Drive
Charlotte, NC 28262
1-877-4electrolux (1-877-435-3287)
electroluxappliances.com
CANADA
5855 Terry Fox Way
Mississauga, ON L5V 3E4
1-800-265-8352
electroluxappliances.ca
EI15IM55G 10/10 © 2010 Electrolux Home Products, Inc. Printed in the U.S.A.
Under-Counter Ice Maker Specifications
Product Weight – 100 Lbs.
Voltage Rating –120V/60Hz/15 Amps
Connected Load (kW Rating) @120 Volts = 0.48kW
(For use on adequately wired 120V, dedicated circuit having 2-wire
service with a separate ground wire. Appliance must be grounded
for safe operation.)
Run Amps @120 Volts=4 Amps/Harvest Amps @120 Volts=5.5 Amps
Electrical cable supplied.
Water supply and electrical power source required.
Always consult local and national electric & plumbing codes.
Unit is designed for either freestanding or built-in, under-counter
installation.
Built-in, under-counter installation does not require additional airspace for
top, sides or rear of unit.
Allow 1-1/2" minimum clearance behind unit for electrical, water
supply and drain connections.
Front grille MUST remain unobstructed for proper ventilation.
Can be installed using gravity drain or optional Drain Pump Kit
(PN# EIMP60).
Drain lines must have 5/8" inside diameter, 1" drop per 48" (1/4" per
foot) of run and must not create traps.
Floor drain must be large enough to accommodate drainage from
all drains.
Recommended water pressure between 30 and 120 pounds
per square inch (psi).
Unit MUST be level for proper operation, and positioned on flat surface,
capable of supporting entire weight when fully loaded.
Leveling legs supplied to adjust height and level unit.
Can be installed outdoors, out of direct sunlight. Do NOT install behind
closed doors.
Do not position unit near any heat source or in direct sunlight to ensure
optimum performance. Surrounding air temperature must be at least
50°F but must not exceed 110°F.
Unit requires zero clearance when installing flush with cabinet or wall.
When installing against cabinet or wall that extends beyond front edge
of unit, 2-7/8" minimum handle clearance required to allow for 90° door
swing, providing sufficient interior access. (Door is field reversible for
right- or left-hand opening.)
Note: For planning purposes only. Refer to Product Installation Guide
on the web at electroluxappliances.com for detailed instructions.
Optional Accessories
Drain Pump Kit – (PN# EIMP60).
Cleaning Kit – (PN# EIM41978).
Page view 1
1 2

Comments to this Manuals

No comments