Document number: page 2 (3)
1. Heating element power
230V: 28.5-29.7, 240V: 30.9-32.2 ohm
2. Visual heating element inspection.
3. Line voltage.
4. Levelling of the machine.
5. Drain installation.
6. Water supply.
7. Leakage at drain and inlet valve.
8. Calibration of water level scale.
Mandatory Measured After
adjust
R1 ohm
R2 ohm
R3 ohm
Visual OK
L1-L2
L1-L3
L2-L3
lf-lr < 5 mm
rf-rr < 5 mm
lf-rf < 5 mm
lr-rr < 5 mm
d (mm) > 50 mm
P (bar) 2-6 bar
Filltime 60-75 sec
Leakage 0 ± 1 mm
Level 0-200 mm