For UK use only
Connection via Min. size Cable/flex Cable/flex type Fuse
Cooker Control Circuit 2,5 mm² PVC/PVC twin and
earth
min: 15 A
max: 20 A
It is necessary that you install a double pole
switch between the oven and the electricity
supply (mains), with a minimum gap of 3 mm
between the switch contacts and of a type
suitable for the required load in compliance
with the current regulations.
The switch must not break the yellow and
green earth cable at any point.
Important! After installation and connecting,
the cable must be placed so that it cannot at
any point reach a temperature of more than
50°C above the ambient temperature.
Before the oven is connected, check that the
main fuse and the domestic installation can
support the load; and that the power supply
is properly earthed.
The manufacturer declines any respon-
sibility should these safety measures
not be carried out.
Installation
Important! IMPORTANT
The new appliance may only be installed and
connected by a qualified installation engi-
neer.
Please comply with this instruction. If you do
not, any damage resulting is not covered by
the warranty.
Safety information for the installer
The set-up of the electrical installation is
arranged so that the appliance can be iso-
lated from the mains with a minimum 3 mm
all-pole contact separation.
Suitable isolation devices include, for ex-
ample, circuit breakers, fuses (screw type
fuses are to be removed from the holder),
RCDs and contactors.
Anti-shock protection must be provided by
the installation.
The built-in unit must meet the stability re-
quirements of DIN 68930.
Built-in cookers and cooking surfaces are
equipped with special attachment sys-
tems. For safety reasons, they must only
be combined with appliances from the
same manufacturer.
The use of heat protection strips is prohibited
for cookers and ovens with Pyrolytic, if the
recess has a rear wall and closed ground-
level compartment.
However installation is possible with a
ground-level compartment that has been
shortened by at least 20 mm and which has
base ventilation of the same cross-section.
electrolux 33