Fuse 10 A
IP classification IP 24
Temp. selector 30-70ºC
Timer control 4 hours
Max. total power 2050 W
Tot. length of drying space 18m
Load capacity 4 kg (dry weight)
9. TROUBLESHOOTING
Problem Possible cause
The fan does not operate Make sure that the timer is on
Make sure that the mains plug is connec‐
ted to the mains socket
Make sure that no fuses have blown
Make sure that no items has blocked the
airflow around the heating unit and air in‐
let on top of the cabinet , causing thermal
fuse cut out
No heating in the dryer cabinet Make sure that the temperature control is
set at the required temperature
Make sure that no items has blocked the
airflow around the heating unit and air in‐
let on top of the cabinet, causing thermal
fuse cut out
If the advice does not lead to
the desired result, call the
nearest Authorised Service
Centre.
9.1 Thermal fuse cut out.
The thermal fuse cut out if the
temperature is to high in the heating unit.
To restart the drying cabinet, turn the
timer control to "0", then after about five
minutes turn it to the required drying
time.
10. ENVIRONMENTAL CONCERNS
Recycle the materials with the symbol
. Put the packaging in applicable
containers to recycle it. Help protect the
environment and human health and to
recycle waste of electrical and electronic
appliances. Do not dispose appliances
marked with the symbol with the
household waste. Return the product to
your local recycling facility or contact
your municipal office.
*