Anti-cold air function
In HEAT mode, the indoor fan will not
operate in order to prevent cold air from
blowing out if the indoor heat exchanger
does not reach a certain temperature in
one of the following situations:
t when the heating operation starts;
t when the defrosting operation is
t when heating at low temperature.
Gentle breeze
The indoor unit may blow gentle breeze
and the horizontal louvre rotates to a
certain position in one of the following
situations:
t In HEAT mode, the compressor does
not start operation after switching on
the unit.
t In HEAT mode, the temperature
reaches the set value and the
compressor has stopped operation
for 1 minute.
Opetaring temperature range
The operating temperature range for
cooling-only units is -15-(+48)˚C. The
operating temperature range for heat-
pump units is -20-(+24)˚C.
Tip for energy saving
t Do not overcool or overheat. Setting
the temperature at a moderate level
helps energy saving.
t Cover windows with a blind or a
curtain. Blocking sunlight and air from
outdoor is favorable for cooling.
t Clean air
every two weeks.
Clogged air filters lead to inefficient
operation and energy waste.
Tip for relative humidity
t If the unit is operated in an area with
a relative humidity of more than 80%
for a long time, condensate may drip
from the indoor unit.
Installation notes
t Not following the instructions can
cause personal injury and/or property
damage.
t Not following the instructions can
cause the unit to fail.
t Let the unit be installed by an
authorised service centre.
t Let the unit be installed in compliance
with local and governmental
regulations.
t Let the unit be installed according to
the instructions from this manual.
t First contact an authorised service
centre before relocating an already
installed unit
t Disconnect power before working on
the unit.
t Let the mains cable be repaired by an
authorised service centre or qualified
technician for units with Y-attachment.
t The mains plug must remain
accessible after installation.
t Keep
distance between
the interconnection cable and the
Indoor side (°C) Outdoor side (°C)
Max. cooling 32 48
Min. cooling 21 -15
Max. heating 27 24
Min. heating 20 -20
INSTALLATION