Electrolux EWM21xx Service Manual Page 14

  • Download
  • Add to my manuals
  • Print
  • Page
    / 95
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 13
5.2
Reading the alarm codes
It is possible to display the last three memorised alarms in the FLASH memory of the electronic board:
Enter diagnostic mode (par. 4.1)
Irrespective of the type of PCB and configuration:
turn the programme selector clockwise (version with knob) pushing button P1 (version INPUT)
to the tenth position.
The last alarm is displayed.
To display the previous alarms, press sequentially the left button of the START/PAUSE button (as
represented in figure).
To return to the last alarm, press the START/PAUSE button.
5.2.1 Alarm displaying - Citirea codurilor de eroare
AEG Version:
The alarm is displayed by a repeated flashing sequence of the LED placed above
the button START / PAUSE with yellow and red light (0.5 seconds on, 0.5
seconds off with a 2.5 second pause between the sequences).
LED indicator START / PAUSE with yellow light indicates the first digit of
the alarm code (family). Ledul GALBEN de la START/PAUZA indica primul digit al codului de
eroare
LED indicator START / PAUS with red light indicates the second digit of the alarm code (internal
number of the family). Ledul ROSU de la START/PAUZA indica al doilea digit al codului de eroare
These two LEDs are featured in all models.
Other versions:
The alarm is displayed by a repeated flashing sequence of the START / PAUSE
button with red and green light (0.5 seconds on, 0.5 seconds off with a 2.5
second pause between the sequences).
LED indicator START / PAUSE with red light indicates the first digit of the
alarm code (family)
LED indicator START / PAUSE with green light indicates the second digit
of the alarm code (internal number of the family)
These two LEDs are featured in all models.
07-2010 SOI/DT-mdm FCPD-dp Quality-fz
14/95
599 70 56-70
Page view 13
1 2 ... 9 10 11 12 13 14 15 16 17 18 19 ... 94 95