Setting up
• StandardEN378specifiesthattheroominwhichyouinstall
your appliance must have a volume of 1 m
3
per 8 g of R 600a
refrigerant used in the appliance, so as to avoid the formation of
inflammablegas/airmixturesintheroomwheretheappliance
is located in the event of a leak in the refrigerant circuit. The
quantity of refrigerant used in your appli-
ance is indicated on the type plate on the
inside of the appliance.
•Onlyusetheappliancewhenitisinstalled.
•
Do not cover ventilation openings
or grille.
Switching the appliance on and o
Switching the appliance on
Press the On/Off button until the temperature display
lights up.
Switching the appliance o
Keep the On/Offbuttonpressedforapprox.3secondssothat
the temperature display goes out.
1 Temperature display (display)
2 Temperature setting buttons
3 On/Obutton
4 Action Cool button (The Action Cool button switches the re-
frigeratorcompartmenttomaximumcooling)
5Audiblewarningon/obutton
Symbols in the display
Setup mode is activated (activating the child lock)
Child lock is activated
Symbol ActionCool on
Demo mode is activated
Operating and control elements
The electronic control panel has the "touch capacitance tech-
nology".
Any function can be activated by touching the corresponding icon.
Climate rating
The climate rating indicates the room
temperature at which the appliance may
be operated in order to achieve full refrig-
eration performance.
The climate rating is indicated on the
type plate.
The position of the type plate is shown in the section entitled
Description of the appliance.
Climate rating Room temperature
SN-ST +10°Cto+38°C
SN-T +10°Cto+43°C
Do not operate the appliance outside the
specified room temperature range.
Electrical connection
Only operate the appliance with alternating current (AC).
The permissible voltage and frequency are indicated on the type
plate. The position of the type plate is shown in the section entitled
Description of the appliance.
The socket must be properly earthed and protected by a fuse.
The tripping current of the fuse must be between 10 A and 16 A.
The socket must not be situated behind the appli-
ance and must be easily accessible.
Donotconnecttheapplianceusinganexten-
sioncableorextensionsocket.
Do not use stand-alone inverters (conversion
of direct current to alternating current/three-
phase current) or energy-saving plugs. Risk
of damage to the electronic control system!