Electrolux FSF 650 Specifications Page 14

  • Download
  • Add to my manuals
  • Print
  • Page
    / 44
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 13
FSF-ed5006
14
FSF
6. Maintenance
6.1. Maintenance allowed to the user
WARNING: Before performing any maintenance on the
machine, disconnect from electric power.
6.1.1. Every week
• Cleanmachinebodywithasoftnonabrasivecloth.
WARNING: Do not use aggressive detergents or sol-
vents that may ruin machine parts
• Verifyvisuallythatsteam,condensateandcompressedaircon-
nections do not leak
• Verifythatvisibleelectricalcablingandairandsteamconnec-
tion tubing are in perfect working order
• Verifythatpadsandcoversareingoodcondition.Iftheyshow
any sign of deterioration replace them immediately. Pressing
quality may decrease dramatically if pads and covers are dirty
or damaged.
WARNING: Do not run a machine that does not look in
proper order
INDICATION: always ask for original spare parts. Non
original parts may damage to the machine or decrease
its safety
Mainenance
6.1.2. Every six months
Call the authorised technician to perform the maintenance opera-
tions described in the following chapter.
6.2. Maintenance to be carried out by the
technician every six months
WARNING: The maintenance operations described in this
chapter must only be carried out by qualified personnel.
WARNING for the technician:
Before any kind of maintenance or control intervention:
• Disconnectthemachinefromelectricity,airandsteam
• Dischargeairpressurefromthepneumaticcircuitbyopening
the valve at the air inlet
• Makesurethatallthepartsofthemachinehavecooleddown
6.2.1. Electrical circuit maintenance
• Verifythatelectricalconnectionsareproperlytightenedanddo
notshowoxidation;
• Verifytighteningofsolenoidvalvecoils;
• Verifystateofcableandelectricalwiringconditions.
6.2.2. Steam circuit maintenance
• Verifythatsteamandcondensatereturnconnectionsareprop-
erly tightened and do not leak
• Verifythatsteamvalveisingoodworkingorderanddoesnot
present leakage
6.2.3. Air circuit maintenance
• Verifythatvalvesandcylindersdonotshowanylossofair;
6.2.4. Other controls
• Checkthatfanbladesarefreeofdirtandlintdeposits.
Use only Original spare parts.