Spares Operation 08.01 A. B. 599 51 19 69 EN
Routine 4 see basic setting 1 5
4
white
routine number
000
error code
red
When the power supply is interrupted after the detection of the malfunction, the information is cancelled
and with the execution of the test routine no. 4, the error code 000 appears. If a malfunction has been
detected, but the reason for that malfunction does not exist any longer (passing malfunction), as the
temperature dropped resp. the cooking thermometer was plugged off, the error code is noticed in the
memory and, until the power supply is not interrupted, the respective error code can be read via the test
routine no. 4.
Error messages (routine 4)
Description of function:
If it is asked, this module handles all arisen faults and executes an EEPROM check. When a defect
arises, an error register has access to the main loop of the processor control. This results in the control
switching from the current state to the error mode (except when it is in the test mode). If a new fault
arises, which has a higher priority than the previous one, only the new one (higher error code) is
indicated. The last occurred fault with the highest priority is saved and can be indicated at any time by the
service test mode 4. The defect with the highest priority is the EEPROM check error F.
Error code Type of malfunction
000 no malfunction
001 food thermometer open infinite ohm
002 food thermometer short circuit 0 ohm
003 Arises when trying to switch on again the appliance
despite the error code indication 002 resp. 003.
Malfunction with the protective circuit.
004 Arises when the child lock is to be switched on, but
the circuit is defective.
005 not covered
006 The temperature measured by the oven sensor exceeds
that temperature which is set by the programming device.
007 Further checks of cooking cabinet probe and the
display board probe, except disconnection and short
circuit (checking error)
008 Temperature limiter with the board has triggered off.
009 Temperature limiter with the board is short-circuited.
00 A Temperature limiter with the board is open.
00 B not covered
00 C not covered
00 D oven sensor short-circuited
00 E oven sensor disconnected
00 F EEPROM error (microprocessor)
Page view 28