Technical Manual EMP 8x0.00/04/13 v5 wh Münzprüfer Dietmar Trenner GmbH, Germany
Version 1.51
Page 34/42 subject to technical modification EMP8x0.00/04/13 v5
the power on Reset, because this information must be transferred first after the poll
command. There may not be enough time to do this if the coin selector has to be
instantly ready to accept coins.
A coin type command, which is sent from the machine controller to the coin
selector is stored in the EEPROM in this mode and therefore still valid after a
power on reset until the next coin type command is received.
3.3.4.2 Polling
The coin selector only turns itself off after accepting a coin and after the
information has been retrieved by the polling machine controller. However, the coin
selector will turn itself off after two seconds if this polling does not happen.
A special procedure must be followed to send a coin type command to a battery
operated coin selector. The coin type command must be sent after switching the
device on and before a polling command, because otherwise the coin selector will
turn itself off first.
As an alternative, the polling can be sent, but without responding to the ACK sent
by the coin selector. The coin selector will also not turn off in this case, and so the
coin type command can still be received. In this case the polling can be sent again,
and the coin selector will respond as it did the previous time. This second polling
must then be responded to with the ACK, at which point the coin selector will turn
itself off.