EElleeccttrroonniicc CCoonnttrrooll
3-6
SSeerrvviiccee DDiiaaggnnoossttiicc MMooddee
IInniittiiaattee SSeerrvviiccee MMooddee
The service technician should set the temperature to 0 F, then press and hold both the
++
and
--
keys
simultaneously for 3 seconds.
When the diagnostics mode is entered, the number "88" is displayed and the confirmation tone is sounded.
The status information will be displayed for 3 seconds and then return to the diagnostics indicator.
MMooddeell IIddeennttiiffiiccaattiioonn
Press the plus (
++
) key to display the model number.
Once you have displayed the model ID, press and hold
the plus (
++
) and
ffaasstt ffrreeeezzee
keys for 3 or more seconds
to select the option to change the model ID. The model
ID will increment or decrement by pressing the
++
or
--
key. The model ID can be saved immediately by
pressing
mmuuttee ssoouunnddss
key.
SSooffttwwaarree VVeerrssiioonn
Press the
ffaasstt ffrreeeezzee
key to display the production software version for the model. (The limitation is 00 - 99
production software versions per model.) The minus and 2 digit version number "-xx" is displayed.
DDoooorr SSwwiittcchh SSttaattuuss
Press the "
--
" key to display the door switch status.
If the door switch is open, the letter "
ddOO
" is displayed.
If the door switch is closed, the letter "
ddCC
" is displayed.
TThheerrmmiissttoorr SSttaattuuss
Press the mute sounds key to display the thermistor status.
If the thermistor is operating properly, the characters "
-- --
" are displayed.
If the thermistor is open, the letter "
ttOO
" is displayed.
If the thermistor is shorted, the letter "
ttSS
" is displayed.
The thermistor status is not updated in showroom mode. The characters "
-- --
" are always displayed
RReesseett FFaaccttoorryy DDeeffaauullttss
Press the
ffaasstt ffrreeeezzee
key while the software version is displayed to reset all EEPROM values to the factory
defaults. The model ID will not be affected. The user interface will exit diagnostics mode and automatically
restart in normal power up operation.
EExxiitt DDiiaaggnnoossttiicc MMooddee
To exit service mode, the service technician should press and hold both the
++
and
--
keys simultaneously for 3
or more seconds. The buzzer beeps at the end of 3 seconds.