15ENGLISH
2. During the Heating mode, you will need
to connect a drain hose to the rear of
unit as Fig.26
Additional things you should know
Now that you have mastered the operating
procedure, here are more features in your
control that you should become familiar
with.
t The “Cool” circuit has an automatic
3minute time delayed start if the unit is
turned off and on quickly. This prevents
overheating of the compressor and
possible circuit breaker tripping. The fan
will continue to run during this time.
t The control will maintain the set
temperature within 1 °C, between
t 17 °C and 30 °C (62 °F and 86 °F).
t The control is capable of displaying
temperature in degrees Fahrenheit or
degrees Celsius. To convert from one to
the other and back, press and hold the
“TEMP” Up (
) and Down ( ) buttons
together for 3 seconds.
t After a power outage, the unit will
memorize the last setting and return the
unit to the same setting once power is
restored.
Continious
drain hose
Fig. 26
7. CARE & CLEANING
Clean your air conditioner occasionally to
keep it looking new. Be sure to unplug
the unit before cleaning to prevent
shock or re hazards.
7.1 Air Filter Cleaning
t This unit has two lters, they are lter A
and B. Grasp the upper panel tab and
take off the lter A which behind the grill
of the back panel (Fig. 27). Remove the
lower lter B by loosening the screw.
Take down the air inlet grille, then
remove the air lter as shown in Fig.28.
Fig. 27
Filter A
Fig. 28
Filter B
Slide out the lter B
behind the side panel
Remove the
screw and take
the air intake
grille down
Page view 14