Page view 62
Fitted Equipment
When using electric heating the caravan
temperature is regulated by the thermostat
mounted at the top of the installation box but
when using the gas heating the temperature
is controlled by the gas heater thermostat.
The night setting is a 1kW convector heater
setting. In the summer the fan may be
operated without any heat input to distribute
cool air.
The Fanmaster has an air deflector allowing
the majority of air to be directed down one
fan outlet. For example, down the longest
ducting run. This may have been preset on
installation.
The duct outlets are generally of the butterfly
type and may be opened or closed by
adjusting the butterfly valves. Twisting the
disc in its housing directs the flow in the
direction required. One outlet on each leg of
the duct layout must be kept open.
Servicing
In order to ensure that your heater continues
to operate effectively, you will need to
arrange for it to be serviced at least once a
year by a competent and trained service
engineer. By law no one is permitted to deal
with the installation and servicing of gas
appliances unless they have proven
competence. Contact your nearest
authorised caravan distributor if service or
repair is required.
FANMASTER CONTROLLER OPERATIONS - SLIDE SWITCH ON HEATER TOP
(R.H. INSTALLATION)
POSITION OPERATION (without gas) OPERATION (with gas)
0 Off Gas convector
Manual fan speed - Temperature Blown hot air distribution
1 slider governs the fan speed.
For cool air distribution.
1kW electric convector heating, Electric and Gas convection, but a high gas
2 no fan. Temperature slider heater output will inhibit the electric heating
selects desired room temperature to maintain safe operating temperatures.
1kW electric fan heating, Electric and Gas blown distribution. Fan
3 fan remains slow. speed adjusts automatically based on
outlet temperature.
2kW electric fan heating. Fan Electric and gas blown distribution. Fan
4
automatically adjusts speed to suit. speed adjusts automatically.
60
FANMASTER CONTROLLER OPERATIONS - WALLSWITCH CONTROL
(L.H. INSTALLATION)
POSITION OPERATION (without gas) OPERATION (with gas)
0 Off Gas convector
Manual fan speed - Wall switch Blown hot air distribution
1 knob governs the fan speed.
For cool air distribution.
Automatic fan speed, temperature Blown hot air distribution with automatic
2
of heater governs fan speed. fan speed control.
1kW electric convector heating, no Electric and Gas blown distribution. Fan
3 fan. Wall switch knob selects speed adjusts automatically based on
desired room temperature. outlet temperature.
1kW electric fan heating, fan Electric and gas blown distribution. Fan
4
remains slow. speed adjusts automatically.
2kW electric fan heating. Fan
5
automatically adjusts speed to suit.
Page view 62