Electrolux A552KA User Manual Page 6

  • Download
  • Add to my manuals
  • Print
  • Page
    / 12
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 5
6
The refrigerator is equipped for a specific gas-pressure, corresponding to the
standard pressure of the country in which it is sold. The rating-plate states the
pressure which is correct. It is important that a non adjustable pressure-regulator
is used to reduce the pressure in the gas cylinder to the operating pressure
specified on the rating-plate, no other pressure may be used.
Needle valve operated gas control taps are NOT suitable for use with this
appliance and must not be used as a substitute for a pressure regulator.
9. Connection of gas supply
Always connect in the following sequence:
GAS BOTTLE
PRESSURE-REGULATOR
APPLlANCE.
The gas bottle must only be used in an upright position and particular care must
be taken every time the appliance is connected to the gas bottle to ensure that
there are no leaks, that the gas pipe (rubber hose) is not under tension or kinked,
and that it is not in contact with hot surfaces.
The connection pipe and gas bottle should always be located in positions where
they will not be tripped over or otherwise inadvertently disturbed.
Before attempting to light the burner, every time after connection, turn on the gas
at the bottle and check the gas connections for leaks by applying a soap and water
solution over them and watching for bubbles, which would indicate a leak.
For your safety
Do not check for leaks with a naked flame!
Do not smoke while checking for leaks!
10. Gas equipment (Fig, 1)
This consists of a control knob (B) with built-in safety pilot, a burner with igniter
plug and a piezo-gas igniter (E).
The control knob (B) has three positions:
: high flame (MAX) = gas supply open;
: low flame (MIN) = reduced gas supply;
: off-position = gas suppty to burner is shut off.
If, for any reason the gas flame extinguishes the ignition control is working
automatically and shuts off gas supply.
11. Igniting the gas burner (Fig. 1/2)
1. 3-way-switch (D) should be in position '0'.
2. Open gas cylinder or pressure regulating valve.
3. Turn knob (B) anti-clockwise to the MAX position, press and hold down.
Page view 5
1 2 3 4 5 6 7 8 9 10 11 12

Comments to this Manuals

No comments