Something Not Working
Before contacting your local Service F orce Centre check the following points:
Symptom Solution
"" is displayed in the temperature
display.
An error has occurred in measuring the temperature. Call your
service representative. (The cooling system will continue to
keep food products cold, but temperature adjustment will not
be possible.)
The temperature is too high inside the
refrigerator.
Set a lower temperature.
Put food products in the right place inside the refrigerator. See
the chapter "Temperature inside the refrigerator".
Distribute the food products to allow cold air to circulate
around them.
Make sure that the door is completely closed and that the
rubber door seal is complete and clean.
It is too cold inside the refrigerator. Set a warmer temperature.
Water comes out on the floor. Place the drain hose at the back of the appliance above the
drain bowl. S ee the chapter "Before use"
The compressor operates continuously. Set a warmer temperature.
Make sure that the door is completely closed and that the
rubber door seal is complete and clean.
The cabinet does not operate at all.
Cooling or interior light does not
operate. No indicator lamps light.
Power does not reach the appliance. (Try connecting another
electrical device to the power outlet.)
The appliance is not switched on.
The fuse has blown.
The power plug is not properly connected.
Noise The refrigerating system will always produce some sounds. A
pulsing sound is heard when coolant i s pumped inside the
cooling pipes. A ticking sound from the thermostat can be
heard when the compressor s witches on and off. The sound
level varies depending on the operation of the cabinet.
If you feel the sound level is incorrect:
Make sure the pipes at the back of the cabinet not touch each
other. Carefully bend them if they do.
If the cushion spacers (between the cabinet wall and pipes)
come loose, put them back in place again.
Carefully follow the instructions in the chapter "Installing the
cabinet".
Not enough carbon dioxide in the water Incoming water pressure too low.
Drain off a large amount of carbonated water (about 1 litre)
The carbon dioxide is running out. Replace the gas cylinder.
Storage temperature too high. Lower the temperature in the
refrigerator.
Too much carbon dioxide in the water Dilute with ordinary water. (See the section "The water
dispenser functions")
No carbon dioxide. The gas cylinder is empty. Replace the gas cylinder.
Drain off a large amount of carbonated water (about 1 litre)
Incoming water pressure too low.