Electrolux IK293SR B User Manual Page 75

  • Download
  • Add to my manuals
  • Print
  • Page
    / 84
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 74
75
GB
10/6 = 1270 mm
12/6 = 1524 mm
Installation dimensions
In this area, the power cord comes out of the appliance rear.
Free length of the power cord = 2000 mm
Choose the position of the socket considering these specifications.
The socket must not be situated behind the appli-
ance and must be easily accessible.
Important
In order to avoid any problems when installing the appliance and
to avoid damage to the appliance, the following conditions must
be complied with.
The kitchen unit must be aligned horizontally and
vertically.
Minimum wall thickness of the body of the unit = 16 mm.
Important
The minimum recess depth of 575 mm applies to the
installation option with external door panel.
In the case of the installation option with internal
door panel, the panel thickness must be added to
the 575 mm.
Appliance venting
Important
The clear ventilation cross-
section must be at least
200 cm² from the lower ven-
tilation opening right to the
upper one.
Types of air outlet
1 Directly above the appliance
2 Above the top unit
3 From the front of the top unit with decor grille
Important
When using decor grilles, it must be taken into account
that the clear ventilation cross-section corresponds
to the sum of the individual openings in the grille.
A cut-out section of merely 200 cm² for installing the
ventilation grille is thus not sucient.
Page view 74
1 2 ... 70 71 72 73 74 75 76 77 78 79 80 ... 83 84

Comments to this Manuals