Technical Manual EMP 8x0.00/04/13 v5 wh Münzprüfer Dietmar Trenner GmbH, Germany
Version 1.51
Page 12/42 subject to technical modification EMP8x0.00/04/13 v5
Figure 4 Calibration window for EMP 800 v5 coin selector
The calibration mode “fix” is intended for use with coins and coin channels for
which preset tolerance parameters are available and calibration mode “fix” is also
preset. As a general rule, “fix” provides the best results when such information is
already available.
The coin tolerances are automatically adjusted to the test coin set when “narrow”,
“average” or “broad” are chosen. This makes them particularly appropriate for the
calibration of new coins or tokens in the absence of coin data sets.
Each of the calibration ranges approximates coin acceptance as follows:
narrow approx. 95%,
average approx. 98%,
broad approx. 99%.
Obviously, the actual acceptance rate in a vending application may vary from the
figures above. The level of variation relates directly to just how the coin set used
for calibration is typical of the coins currently in circulation.
The number of inserted coins as well as the overall number of coins required is
shown in the calibration window. The total number of required coins is determined
by the data file. Calibration automatically ends once the required number of coins
have been inserted and the procedure may now be finished or another coin
channel selected for calibration.
2.2.1.2 Calibration Using the Teach Mode Function (Option /T)
The coin selector can be delivered with an optional teach mode function (on site
programming). The teach mode can be set up for a maximum of 14 channels at the
factory. No PC is required for the teach mode, since the necessary software is built
into the coin selector.
The teach mode is activated by setting the number 8 switch on the bottom row of
DIP switches to “ON”. The number 7 switch of the same DIP switch block is used
to set the acceptance tolerance to “broad” or “narrow”. The “ON” setting selects a
narrow tolerance.
To start the calibration it is necessary to select a channel to be calibrated by
setting one channel switch to “ON”. The left DIP switch in the bottom row
corresponds to channel 1 and right DIP switch in the upper row corresponds to
channel 16.
The coin channel must be chosen after
activation of the teach mode switch 8. The
advantage is that it is not necessary to set all DIP switches to “OFF” first before
programming a particular channel.