Fig. 4
Fitted Equipment
One outlet on each leg of the air ducting
layout must be kept open at all times.
Note:
Mains hook-up is needed for positions 2, 3
and 4, the current consumption will be
approximately 4 amps for positions 2 & 3 and
approximately 8 amps for position 4.
If you suspect that your mains hook-up is
inadequate to supply the 8 amps required for
position 4 in addition to your existing mains
load, then for initial warm-up, use the Carver
gas heater on a high setting and the
Fanmaster on the position 1 setting.
When comfortable change to either positions
2 or 3 and turn the gas heater off.
Typical mains current consumption is:
Carver Cascade 2 water heater 3.6A approx.
Travelling kettle 3.2A approx.
Battery charger 1.0A approx.
Portable colour TV 0.3A approx.
60w light bulb 0.3A approx.
Fanmaster on position 4 8.3A approx.
Fanmaster on position 2 or 3 4.2A approx.
The normal mains supply to UK sites are
rated at 16A but some sites have only a 10A
capacity.
Servicing
In order to ensure that your heater continues
to operate effectively, you will need to
arrange for it to be serviced at least once a
year by a competent and trained service
engineer. By law no-one is permitted to deal
with the installation and servicing of gas
appliances unless they have proven
competence. Contact your nearest caravan
distributor if service or repair is required.
Safety
To prevent over-heating of the electric
elements at least one warm air outlet must
be open at all times. It is recommended that
one outlet should be of the non-closable
type and not a butterfly.
If all the outlets are closed the self-hold
thermal trip will switch off the power to the
elements. If this happens, open the outlets,
switch the heater power off and wait until the
unit has cooled down, the unit will then reset
itself.
Make sure that clothing etc. is kept clear of
the back of the heater.
62
FANMASTER CONTROLLER OPERATIONS (Fig. 2)
POSITION OPERATION (without gas) OPERATION (with gas)
0 Off Gas convector
Manual fan speed - Temperature Blown hot air distribution
1 slider governs the fan speed.
For cool air distribution.
1kW electric convector heating, Electric and Gas convection, but a high gas
2 no fan. Temperature slider heater output will inhibit the electric
selects desired room heating to maintain safe operating
temperature. temperatures.
1kW electric fan heating, Electric and Gas blown distribution. Fan
3 fan remains slow. speed adjusts automatically based on
outlet temperature.
2kW electric fan heating. Fan Electric and gas blown distribution. Fan
4
automatically adjusts speed to suit. speed adjusts automatically.