5. Pull out the emergency emptying cap
from the filter cover, using pliers.
6. When no more water comes out, un-
screw the pump cover by turning it anti-
clockwise, using pliers, and remove the
filter. Always keep a rag nearby to dry up
any water spillages when removing the
cover.
Clean the filter under a tap, to remove
any traces of fluff.
1
2
7. Remove foreign bodies and fluff from the
pump seat and from the pump impeller.
8. Check carefully whether the pump im-
peller rotates (it rotates jerkily). If it
doesn’t rotate, please contact your
Service Centre.
9. Replace the filter into the pump by in-
serting it correctly into the special
guides. Screw the pump cover firmly by
turning it clockwise.