Electrolux SBB800S-1 Installation Manual Page 30

  • Download
  • Add to my manuals
  • Print
  • Page
    / 84
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 29
28
The end of the drain pipe
must have an air gap.
Slope pipe downwards
1/4" per foot.
1/2" PVC pipe
1/2" PVC elbow
3/8" ID tubing*
* Install tubing according to pump
manufacturer's instructions.
Condensate pump
DO NOT ADD
ANY VALVES
Slope pipe downwards
1/4" per foot.
1/2" PVC pipe
The end of the drain pipe
must have an air gap.
Condensate piping to floor drain Condensate piping with pump
Floor drain
MAINTAIN CLEARANCE
DO NOT ADD
ANY VALVES
Electrolux
Condensing
Tankless Gas
Water Heater
Electrolux
Condensing
Tankless Gas
Water Heater
/PUF
If the drain line becomes clogged or frozen, condensate will back-up into the water heater and a "29"
error code will ash on the remote controller, ceasing operation. If this occurs, clear the clog or freeze
so that condensate can freely ow. Be sure to slope the drain pipe, use the appropriate size pipe, allow
the proper clearances, and apply freeze prevention measures (when necessary) to prevent the drain
line from clogging or freezing.
Page view 29
1 2 ... 25 26 27 28 29 30 31 32 33 34 35 ... 83 84