Cleaning the exhaust lter
There are two types of Electrolux Twinclean exhaust lters:
Standard lter. Must be cleaned every 5–7 years.
HEPA lter (thicker with creased bre material). Must be
cleaned every 2–3 years.
There is no dierence in how the lters are cleaned or
tted.
30 Remove the dust container by pressing the release
button at the back of the vacuum cleaner and lifting
the container.
31 Lift the two snap catches at the back edge of the
vacuum cleaner and open the lter cover.
32 Lift out the lter.
33 Rinse the inside (dirty side) in lukewarm tap water.
Tap the lter frame to remove the water. Repeat the
process four times. Note: Do not use cleaning agents
and avoid touching the lter surface.
Let the lter dry.
Put the lter back into place, close the lter cover and
ret the dust container.
Clearing the hose and nozzle
The vacuum cleaner automatically stops if there is a
blockage in the nozzle, tubes or hose or if the lter or lter
holder becomes blocked. Pull out the power plug and
allow the vacuum cleaner to cool down for 20–30 minutes.
Remove the blockage that is causing the problem, and/or
replace the dirty lter. Restart the vacuum cleaner.
34 Use a suitable implement to clear the tubes and hose
of blockages.
35 It is sometimes possible to clear the hose by
“massaging it. However, be careful in case the
obstruction has been caused by glass or needles
caught inside the hose. Note: The warranty does not
cover any damage to hoses caused by cleaning them.
English
If something gets stuck in the vacuum cleaner
If something gets stuck in the vacuum cleaner:
36 Turn o the vacuum cleaner and open the cover at
the front of the unit by lifting the release catch.
37 Lift out the lter holder and the lters.
38 Lift the cover between the lter wells and remove
anything that may have got stuck. Also check the
bottoms of the lter wells for foreign objects.
39 Ret the cover under the catches and close it by
pressing down. Put the lter holder back in place and
close the vacuum cleaner cover.
Cleaning the Max In and carpet/oor nozzles
40 The Max In and the carpet/oor nozzles should be
cleaned frequently to avoid losing suction power. The
easiest way to do this is by using the hose handle.
41 The auxiliary wheels should be carefully pulled
straight out.
42 Clean as required and put them back in the reverse
order.
Cleaning the Max In Turbo and motorized
nozzles
Always unplug the vacuum cleaner from the wall outlet
before cleaning.
43 To remove the brush roller cover, push the outer latch
out, and the middle cover to the left, and this will also
free the wheels for cleaning.
44 Lift out the brush roller and clean it. Remove
entangled threads etc. by snipping them away with
scissors. Ret in the reverse order. The auxiliary wheels
should be carefully pulled straight out. Clean as
required and ret in the reverse order (45).
Cleaning the dust container
The dust container can be thoroughly cleaned when
emptying.
46 Remove the dust container.
47 Empty it.
48 Remove the cover on the side of the round space by
pulling it straight out.
The dust container can now be wiped o or cleaned. If you
use water, make sure that the cartridge is dry before you
put it back. Ret the cover back on by pushing it straight
in. Put back the dust container.