Rooms with a staircase
Trilobite can detect staircases with a step height of 4 inches or
more.When Trilobite detects such a staircase, it stops automatically.
Do not place any objects on the top step.
Rooms on different levels or with inclines.
Trilobite can not detect differences in surface level of less than 4
inches. If a room has such a difference in level – and especially if
it leads to a stairway – it should be blocked with a magnetic strip
to ensure the unit stops before reaching the obstacle.
Rooms with wall openings
Trilobite is able to vacuum rooms with wall openings or walls
placed at odd angles. However, this will take longer than usual.
It is a good idea to vacuum one room at a time and separate the
rooms by using a moveable magnetic strip as shown above.
To prevent Trilobite from pushing the moveable magnetic strip,
the support at each end should be minimum 2 inches.
Always move the magnetic strip to the room where Trilobite is
in operation.
Rooms with thresholds
Always fit the magnetic strip on the floor in front of the threshold
in the room you will be vacuuming. See Figures 1 and 2.
Magnetic strips and carpets
If the carpet has a pile depth of less than 3/4 of an inch, the
magnetic strip can be placed under it with maintained
functionality.
If the strip is fitted on top of the carpet, be sure it is securely
attached.
Be careful!
Before starting Trilobite, be sure to put away small, loose objects
that might otherwise be vacuumed by Trilobite.
Also make sure there are no cords or other objects on the floor
that may prevent Trilobite from moving freely around the room.
NOTE! Do
not place the
magnetic strip
at an angle of
less than 90°.
Affixing the
magnetic strip
Clean the surface
with the enclosed
cleaning pad.
Allow to dry.
Pull off
the protective
backing.
Affix the
magnetic strip.
3.
5.
4.
1.
2.
Room with wall openings
Room with a low ledge
Room with
thresholds
Room with
thresholds
Always attach the magnetic strip on
top of the level difference (Figures 3
and 4) and never along its side
(as shown in Figure 5).
Warning! Credit cards etc.
held in the immediate vicinity
may become demagnetized.