17
Conversion from Natural to LPG Gas
IMPORTANT
The replacement/conversion of the gas hob should
only be undertaken by a CORGI registered engineer.
It is important to note that this model is designed for use
with natural gas but can be converted for use with butane
or propane gas providing the correct injectors are fitted.
The gas rate is adjusted to suit. The oven burner does
not need any primary air regulation.
Replacement of gas oven
burner nozzle
To replace the gas oven nozzle, follow this procedure:
a) remove the bottom of the oven;
b) undo screw a and b and take the oven burner out;
c) with a socket spanner 7 unscrew and remove the
nozzle, situated in the bottom of the oven, and replace
it with the correct one (see Table on this page);
d) reassemble the burner following the same procedure
backwards.
a
b
TYPE OF GAS NOZZLES NOMINAL POWER IN REDUCED BY-PASS GAS NOMINAL MIN MAX
1/100 MM POWER POWER 1/100 MM PRESSURE PRESSURE PRESSURE
KW m
3
/h g/h (KW) (mbar) mbar mbar
114 2,7 257 - 1,1 Reg. 20 17 25
78 2,5 - 180 1,1 52 29 20 35
78 2,5 - 180 1,1 52 37 25 45
Natural gas
(G20)
Butane
(G30)
Propane
(G31)
Fig.8