Appliance venting
Important
The clear ventilation cross-
section must be at least
200 cm² from the lower ven-
tilation opening right to the
upper one.
Types of air outlet
1 Directly above the appliance
2 Above the top unit
3 From the front of the top unit with decor grille
Important
When using decor grilles, it must be taken into account
that the clear ventilation cross-section corresponds
to the sum of the individual openings in the grille.
A cut-out section of merely 200 cm² for installing the
ventilation grille is thus not sucient.
Installing the appliance
1.
Fit cover profile.
On appliances with
hinges on the right
On appliances with
hinges on the left
2.
Slide the appliance into the recess.
Route the mains cable towards the
socket.
When sliding in the appliance, make sure
that the mains cable is not damaged.
Installation option with external door panel
A = max. 43 mm
Installation option with internal door panel
A = 43 mm + panel thickness
1.
2.